Altronix | SKU:
T3KAK33F16
Altronix T3KAK33F16 TROVE3KA3, 16-DR, 12A, FUSE
Regular price
$1,700.49
Unit price
/
Unavailable
Altronix T3KAK33F16 TROVE3KA3, 16-DR, 12A, FUSE is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Care information
Care information
Display general product information or specific product information using metafields.
Delivery and Shipping
Delivery and Shipping
Add some general information about your delivery and shipping policies.
Highlight title
Text to highlight a key feature of your product
Description
Description
T3KAK33F16 TROVE3KA3, 16-DR, 12A, FUSE
Altronix T3KAK33F16 kit consists of Trove3 enclosure and TKA3 Keyscan/Altronix door backplane with two (2) 12 or 24VDC @ 6A power supply/chargers, two (2) 8-output fused access power controllers, one (1) 4-output fused power distribution module and one (1) 16VAC transformer.
This kit also accommodate various combinations of Keyscan boards for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. eFlow6NB Power Supply/Charger Input Voltage: 120VAC, 60Hz, 3.5A max. Input Fuse: 5A / 250V. Outputs Voltage: Factory set at 24VDC. Current: 6A continuous. Auxiliary: Class 2 power-limited @ 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH/12VDC (2 within enclosure); 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. Battery: Discharged or not connected. T16175 Transformer Input Voltage: 115VAC, 50/60Hz, 1.6A. Output Voltage: 16VAC/175VA. 11A supply current. PD4UL Power Distribution Module Input Voltage: 16VAC from T16175. Outputs Voltage: 16VAC. Four (4) fuse protected outputs. 3.5A per output max. Output Fuses: 3.5A/250V. Indicators (LED) Green LED: AC Output. Two (2) ACM8 Access Power Controllers Input Voltage: 24VDC from eFlow6NB. Input Fuse: 10A/250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 152 BTU/Hr.
This kit also accommodate various combinations of Keyscan boards for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. eFlow6NB Power Supply/Charger Input Voltage: 120VAC, 60Hz, 3.5A max. Input Fuse: 5A / 250V. Outputs Voltage: Factory set at 24VDC. Current: 6A continuous. Auxiliary: Class 2 power-limited @ 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH/12VDC (2 within enclosure); 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. Battery: Discharged or not connected. T16175 Transformer Input Voltage: 115VAC, 50/60Hz, 1.6A. Output Voltage: 16VAC/175VA. 11A supply current. PD4UL Power Distribution Module Input Voltage: 16VAC from T16175. Outputs Voltage: 16VAC. Four (4) fuse protected outputs. 3.5A per output max. Output Fuses: 3.5A/250V. Indicators (LED) Green LED: AC Output. Two (2) ACM8 Access Power Controllers Input Voltage: 24VDC from eFlow6NB. Input Fuse: 10A/250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 152 BTU/Hr.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
