Altronix | SKU:
T3HWK7F12
Altronix T3HWK7F12 TROVE3HW3, HW 12-DR FUSE
Regular price
$1,632.53
Unit price
/
Unavailable
Altronix T3HWK7F12 TROVE3HW3, HW 12-DR FUSE is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Care information
Care information
Display general product information or specific product information using metafields.
Delivery and Shipping
Delivery and Shipping
Add some general information about your delivery and shipping policies.
Highlight title
Text to highlight a key feature of your product
Description
Description
T3HWK7F12 TROVE3HW3, HW 12-DR FUSE
Altronix T3HWK7F12 kit consists of Trove3 enclosure and THW3 Honeywell/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) 8-output fused access power
controller, one (1) 4-output fused access power controller, one (1) 12VDC voltage regulator and one (1) 8-output fused dual input power distribution module. Also featured is a rocker
switch bracket with two (2) rocker switches.
Kit accommodates up to six (6) Honeywell 4200 Series or WIN-PAK Series boards and up to two (2) Honeywell PRO22MX8 boards for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. eFlow104NB Power Supply/Charger Input Voltage: 120VAC, 60Hz, 4.5A max. Main Fuse: 6.5A / 250V. Output Voltage: 24VDC. Current: 10A continuous. Auxiliary: Class 2 power-limited @ 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH/12VDC (2 within enclosure) 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from eFlow104NB. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A / 250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. ACM4 Access Power Controller Input Voltage: 24VDC from eFlow104NB. Input Fuse: 10A /32V. Outputs Voltage: 24VDC. Four (4) independently controlled outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3A / 32V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. VR6 Voltage Regulator Input Voltage: 24VDC from eFlow104NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators (LED) Input: 24VDC is present. Output: Powered. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from eFlow104NB. Input Fuse: 10A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A/32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 129 BTU/Hr.
Kit accommodates up to six (6) Honeywell 4200 Series or WIN-PAK Series boards and up to two (2) Honeywell PRO22MX8 boards for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. eFlow104NB Power Supply/Charger Input Voltage: 120VAC, 60Hz, 4.5A max. Main Fuse: 6.5A / 250V. Output Voltage: 24VDC. Current: 10A continuous. Auxiliary: Class 2 power-limited @ 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH/12VDC (2 within enclosure) 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from eFlow104NB. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A / 250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. ACM4 Access Power Controller Input Voltage: 24VDC from eFlow104NB. Input Fuse: 10A /32V. Outputs Voltage: 24VDC. Four (4) independently controlled outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3A / 32V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. VR6 Voltage Regulator Input Voltage: 24VDC from eFlow104NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators (LED) Input: 24VDC is present. Output: Powered. PDS8 Dual Input Power Distribution Module Input Voltage: 12VDC from VR6 and 24VDC from eFlow104NB. Input Fuse: 10A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Outputs Ratings Fuses: 3A/32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 129 BTU/Hr.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.