Altronix T3HWK75F16V TROVE3HW3, HW 16-DR FUSE 220V
Altronix T3HWK75F16V TROVE3HW3, HW 16-DR FUSE 220V is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Care information
Care information
Display general product information or specific product information using metafields.
Delivery and Shipping
Delivery and Shipping
Add some general information about your delivery and shipping policies.
Highlight title
Text to highlight a key feature of your product
Description
Description
T3HWK75F16V TROVE3HW3, HW 16-DR FUSE 220V
Product Details
Altronix T3HWK75F16V kit consists of Trove3 enclosure, THW3 Honeywell/Altronix backplane and THWD2 Honeywell/Altronix door backplane with one (1) 24VDC @ 10A and one (1) 12VDC @ 10A power supply/chargers, two (2) 8-output fused access power controllers and one (1) 8-output fused power distribution module. Also featured is a rocker switch bracket with two (2) rocker switches.
Kit also accommodates up to six (6) Honeywell 4200 Series or WIN-PAK Series boards and up to two (2) Honeywell PRO22MX8 boards for up to sixteen (16) doors in a single enclosure. THWD2 accommodates additional one (1) Honeywell PRO22MX8 and up to six (6) Honeywell 4200 Series or WIN-PAK Series. Trove simplifies board layout and wire management, reduces installation time and labor costs. eFlow104NBV Power Supply/Charger - 1 Input Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.7A. Main Fuse: 6.5A / 250V. Output Voltage: 24VDC. Current: 10A continuous. eFlow102NBV Power Supply/Charger - 2 Input Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.1A. Main Fuse: 5A / 250V. Output Voltage: 12VDC. Current: 10A continuous. Both Power Supplies Outputs Auxiliary: Class 2 power-limited @ 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH/12VDC (2 within enclosure) 40AH/65AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units or 71-73% for 12V units. Prevents deep battery discharge. Indicators (LED) AC Input: 220VAC is present. DC Output: Powered. Two (2) ACM8 Access Power Controllers Input Voltage: 24VDC from eFlow104NBV. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A / 250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. PD8UL Power Distribution Module Input Voltage: 12VDC from eFlow102NBV. Outputs Voltage: 12VDC. Eight (8) fuse protected outputs. 3.5A per output max. Output Fuses: 3.5A / 250V. Indicators (LED) Green LED: DC Output. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 177 BTU/Hr.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.