Altronix | SKU:
T2SSK78
Altronix T2SSK78 24V@10A ULXB/8DR S2 TROVE KIT
Regular price
$970.25
Unit price
/
Unavailable
Altronix T2SSK78 24V@10A ULXB/8DR S2 TROVE KIT is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Care information
Care information
Display general product information or specific product information using metafields.
Delivery and Shipping
Delivery and Shipping
Add some general information about your delivery and shipping policies.
Highlight title
Text to highlight a key feature of your product
Description
Description
T2SSK78 24V@10A ULXB/8DR S2 TROVE KIT
Altronix T2SSK78 kit consists of Trove2 enclosure, TSS2 Lenel-S2 (S2 Security Platform)/ Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) fused access power controller, one (1) voltage regulator and one (1) dual input fused power distribution
module.
This kit also accommodates S2-INST Installation Kit For Lenel-S2 (S2 Security Platform) S2 Network Node for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024ULXB2 Power Supply/Charger Input Voltage: 115VAC, 60Hz, 4.2A max. Main Fuse: 5A / 250V. Output Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure). Type: Sealed lead acid or gel type. Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. PDS8 Dual Input Power Distribution Module Input Voltage: 24VDC from AL1024ULXB2 and 12VDC from VR6. Main Fuse: 10A/32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Output Fuses: 3A/32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from AL1024ULXB2. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from AL1024ULXB2. Input Fuse: 10A/250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 191 BTU/Hr.
This kit also accommodates S2-INST Installation Kit For Lenel-S2 (S2 Security Platform) S2 Network Node for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL1024ULXB2 Power Supply/Charger Input Voltage: 115VAC, 60Hz, 4.2A max. Main Fuse: 5A / 250V. Output Voltage: 24VDC. Current: 10A @ 24VDC continuous max. Other: Overvoltage protection. Filtered and regulated. Battery Charging Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure). Type: Sealed lead acid or gel type. Failover: Upon AC loss, instantaneous. (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. PDS8 Dual Input Power Distribution Module Input Voltage: 24VDC from AL1024ULXB2 and 12VDC from VR6. Main Fuse: 10A/32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Output Fuses: 3A/32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from AL1024ULXB2. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from AL1024ULXB2. Input Fuse: 10A/250V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A/250V. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 191 BTU/Hr.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.