Altronix | SKU:
T2PHK77F24
Altronix T2PHK77F24 TROVE2PH2/24DR/AL/OP/FUS/115V
Regular price
$1,353.80
Unit price
/
Unavailable
Altronix T2PHK77F24 TROVE2PH2/24DR/AL/OP/FUS/115V is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Care information
Care information
Display general product information or specific product information using metafields.
Delivery and Shipping
Delivery and Shipping
Add some general information about your delivery and shipping policies.
Highlight title
Text to highlight a key feature of your product
Description
Description
T2PHK77F24 TROVE2PH2/24DR/AL/OP/FUS/115V
Altronix T2PHK77F24 kit consists of Trove2 enclosure, TCV2 Openpath/Altronix backplane with two (2) 24VDC @ 10A power supply/chargers, and three (3) eight (8) fuse protected output access control modules. This kit also accommodates up to one (1) Openpath Core, two (2) Elevator Board, three (3) 4-Port or 8-Port modules for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Two (2) eFlow104NB Power Supply/Chargers
Input
Voltage: 120VAC, 60Hz, 9A max.
Input Fuse: 6.3A / 250V.
Output
Voltage: 24VDC 10A.
Auxiliary: 1A (unswitched).
Protection: Overvoltage protection. Filtered and regulated.
Battery Charging
Capacity: 12VDC/12AH (2 within enclosure); 40 AH / 65 AH (requires separate enclosure)
Type: Sealed lead acid or gel type
Failover: Upon AC loss, instantaneous
(Batteries are sold separately).
Fire Alarm Disconnect
Supervised: Latching or non latching.
EOL: 10K Resistor.
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Indicators LED
AC Input: 120VAC is present.
DC Output: Powered.
Battery: Discharged or not connected.
Three (3) ACM8 Access Power Controllers
Input
Voltage: 24VDC from eFlow104NB.
Input Fuse: 10A / 250V.
Outputs
Voltage: 24VDC.
Eight (8) 24VDC independently controlled fused outputs:
a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
b) Auxiliary power outputs (unswitched).
c) Any combination of the above.
Output Fuses: 3.5A/250V.
Indicators (LED's)
Red LEDs: Outputs are triggered (relays energized).
Green LED: FACP disconnect is triggered.
Environmental
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):
24VDC: 290 BTU/Hr.
12VDC and 24VDC: 111 BTU/Hr.