Altronix  |  SKU: T2KHK312D

Altronix T2KHK312D TROVE2KH2/12DR/12V/24V@6A/PTC

Regular price $974.07

Altronix T2KHK312D TROVE2KH2/12DR/12V/24V@6A/PTC is backordered and will ship as soon as it is back in stock.


Care information

Display general product information or specific product information using metafields.

Delivery and Shipping

Add some general information about your delivery and shipping policies.

Highlight title

Text to highlight a key feature of your product

Description

T2KHK312D TROVE2KH2/12DR/12V/24V@6A/PTC Altronix T2KHK312D kit consists of Trove2 enclosure, TKH2 Kantech/Altronix backplane with one (1) 12VDC or 24VDC @ 6A power supply/charger, one (1) eight (8) output PTC access power controller, one (1) four (4) output PTC access power controller and one (1) 16VAC/18VAC transformer.
This kit also accommodate various combinations of Kantech boards for up to twelve (12) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs. AL600ULXB Power Supply/Charger Input Voltage: 115VAC, 60Hz, 3.5A max. Fusing: 5A / 250V. Outputs Voltage: 12VDC or 24VDC selectable. Current: 6A @ 12VDC or 24VDC continuous max. Filtered and regulated. Battery Charging Capacity: 7AH / 12VDC (up to 4 within enclosure); 12AH / 12VDC (up to 4 within enclosure); 40 AH / 65 AH (requires separate enclosure) Type: Sealed lead acid or gel type Failover: Upon AC loss, instantaneous (Batteries are sold separately). Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Indicators LED Input: 115VAC is present. DC Output: Powered. Battery: Discharged or not connected. ACM4CB Access Power Controller Input 24VDC from AL600ULXB. Input Fuse: 10A / 32V. Outputs Voltage: 24VDC. Four (4) independently controlled 2A outputs: a) Four (4) Fail-Safe and/or Fail-Secure power outputs. b) Any combination of the above. Four (4) auxiliary power outputs (unswitched). Outputs Ratings PTCs: 2A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. ACM8CB Access Power Controller Input Voltage: 24VDC from AL600ULXB. Main Fuse: 10A / 250V. Outputs Voltage: 24VDC. Eight (8) 24VDC independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. b) Any combination of the above. Output PTCs: 2.5A. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. T1618300K Transformer Input Voltage: 115VAC, 50/60Hz, 2.7A. Output Voltage: 16VAC/300VA (18.7A) or 18VAC/300VA (16.7A). Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity: 85% +/- 5%. BTU/Hr. (approx.): 232 BTU/Hr.

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.