Altronix | SKU:
T1VK34
Altronix T1VK34 TROVE1V1/24V@6A/ULX/FUSED
Regular price
$596.25
Unit price
/
Unavailable
Altronix T1VK34 TROVE1V1/24V@6A/ULX/FUSED is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Care information
Care information
Display general product information or specific product information using metafields.
Delivery and Shipping
Delivery and Shipping
Add some general information about your delivery and shipping policies.
Highlight title
Text to highlight a key feature of your product
Description
Description
T1VK34 TROVE1V1/24V@6A/ULX/FUSED
Altronix T1VK34 kit consists of Trove1 enclosure, TV1 VertX®/Altronix backplane with one (1) 12 or 24VDC @ 6A power supply/charger, one (1) voltage regulator and one (1) dual input fused power distribution module. This kit also accommodates up to two (2) HID Aero/VertX® modules for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
AL600ULXB Power Supply/Charger
Input
Voltage: 115VAC, 60Hz, 3.5A max.
Fusing: 5A/250V.
Outputs
Voltage: 12VDC or 24VDC selectable.
Current: 6A @ 12VDC or 24VDC continuous max.
Other: Overvoltage protection. Filtered and regulated.
Battery Charging
Capacity: 7AH/12VDC (2 within enclosure); 40AH/65AH (requires separate enclosure)
Type: Sealed lead acid or gel type
Failover: Upon AC loss, instantaneous
(Batteries are sold separately).
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Indicators LED
Input: 115VAC is present.
DC Output: Powered.
Battery: Discharged or not connected.
ACM4 Access Power Controller
Input
Voltage: 24VDC from AL600ULXB
Input Fuse: 10A /32V
Outputs
Voltage: 24VDC
Four (4) independently controlled fused outputs:
a) Fail-Safe and/or Fail-Secure power outputs
Form “C” Relays rated 28VAC or VDC @ 2.5A
b) Auxiliary power outputs (unswitched)
c) Any combination of the above
Output Fuses: 3A/32V
Indicators (LED)
Red LEDs: Outputs are triggered (relays energized).
Green LED: FACP disconnect is triggered.
VR6 Voltage Regulator
Input
Voltage: 24VDC from AL600ULXB.
Output
Voltage: 12VDC.
Current: 6A continuous.
Other: Surge suppression.
Indicators LED
Input: 24VDC is present.
Output: Powered.
PDS8 Dual Input Power Distribution Module
Input
Voltage: 12VDC from VR6 and 24VDC from AL600ULXB.
Main Fuse: 10A/250V.
Outputs
Voltage: 12VDC and/or 24VDC.
Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Output Fuses: 3A/32V.
Indicators (LED)
DC Output: Eight (8) individual output LEDs.
Green: 12VDC
Red: 24VDC.
Environmental
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):
87 BTU/Hr.
Payment & Security
Payment methods