Altronix | SKU:
T1KE3F8V
Altronix T1KE3F8V TROVE1 ALTX/KISI 8DR/FUSE/220V
Regular price
$644.87
Unit price
/
Unavailable
Altronix T1KE3F8V TROVE1 ALTX/KISI 8DR/FUSE/220V is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Care information
Care information
Display general product information or specific product information using metafields.
Delivery and Shipping
Delivery and Shipping
Add some general information about your delivery and shipping policies.
Highlight title
Text to highlight a key feature of your product
Description
Description
T1KE3F8V TROVE1 ALTX/KISI 8DR/FUSE/220V
Altronix T1KE3F8V kit consists of Trove1 enclosure and TDR1 Altronix & Kisi backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply/charger and two (2) four (4) fuse protected output access control modules. This kit also accommodates two (2) Kisi Pro Controllers for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
eFlow6NBV Power Supply/Charger
Input
Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.5A.
Main Fuse: 5A / 250V.
Output
Voltage: 24VDC.
Current: 6A continuous.
Other: Overvoltage protection. Filtered and regulated.
Battery Charging
Capacity: 7AH/12VDC (Up to 2 within enclosure) 40AH/65AH (requires separate enclosure)
Type: Sealed lead acid or gel type
Failover: Upon AC loss, instantaneous
(Batteries are sold separately).
Fire Alarm Disconnect
Supervised: Latching or non-latching.
EOL: 10K Resistor.
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Indicators LED
Input: 220VAC is present.
DC Output: Powered.
Battery: Discharged or not connected.
Two (2) ACM4 Access Power Controllers
Input
Voltage: 24VDC from eFlow6NBV.
Input Fuse: 10A /32V.
Outputs
Voltage: 24VDC.
Four (4) independently controlled fused outputs:
a) Fail-Safe and/or Fail-Secure power outputs.
Form “C” Relays rated 28VAC or VDC @ 2.5A.
b) Auxiliary power outputs (unswitched).
c) Any combination of the above.
Output Fuses: 3A / 32V.
Indicators (LED)
Red LEDs: Outputs are triggered (relays energized).
Green LED: FACP disconnect is triggered.
Environmental
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):
90 BTU/Hr.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.