Altronix | SKU:
MAXIMAL11FE
Altronix MAXIMAL11FE 2-EFLOW4NB PWR SPLY
Regular price
$763.90
Unit price
/
Unavailable
Altronix MAXIMAL11FE 2-EFLOW4NB PWR SPLY is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Care information
Care information
Display general product information or specific product information using metafields.
Delivery and Shipping
Delivery and Shipping
Add some general information about your delivery and shipping policies.
Highlight title
Text to highlight a key feature of your product
Description
Description
Altronix MAXIMAL11FE 2-EFLOW4NB PWR SPLY
Maximal11FE Expandable Power System provide system designers and installers with optimum power choices and the highest levels of versatility. They provide 12VDC, 24VDC, or 12VDC and 24VDC simultaneously via two (2) single output power supply/chargers. Includes AC fail, low battery and battery presence monitoring. Enclosure facilitates up to four (4) 12VDC/12AH batteries. All interconnecting equipment must be UL Listed.
Input
120VAC 60Hz, 7.0A input.
Output
12VDC and/or 24VDC outputs.
Maximum output current Options:
A) 12VDC @ 4A plus 12VDC @ 4A.
B) 12VDC @ 4A plus 24VDC @ 3A.
C) 24VDC @ 3A plus 24VDC @ 3A.
Power-limited outputs.
Aux. power-limited output rated @ 1A (unswitched).
Over Voltage Protection.
Fuse Ratings
Power Supply input fuse rated @ 5A/250V.
Fire Alarm Disconnect
Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger.
Supervision
AC fail supervision (form "C" contacts).
Notification trigger is selectable for 30 seconds (factory set) or 2 hours.
Battery fail & presence supervision (form "C" contacts).
Low power shutdown. Prevents deep battery discharge.
Battery Charging
Capacity: 12AH/12VDC (4 within enclosure); 40AH/65AH (requires separate enclosure).
Type: Sealed lead acid or gel type.
Failover: Upon AC loss, instantaneous.
(Batteries are sold separately).
Visual Indicators
Green AC Power LED indicates 120VAC present.
AC input and DC output LED indicators.
Electrical
Temperature:
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.):
12VDC: 48 BTU/Hr.
24VDC: 74 BTU/Hr.
12VDC & 24VDC: 98 BTU/Hr.
System AC input VA requirement: 840VA.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.