{"product_id":"ubiquiti-eav-fiber-enterprise-audio-video-fiber-copy","title":"Ubiquiti EAV-XG-24-PoE (2150W) Enterprise Audio\/Video XG 24 PoE","description":"\u003cp\u003e\u003cstrong\u003eUbiquiti EAV-XG-24-PoE (2150W) Enterprise Audio\/Video XG 24 PoE\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003cp\u003eEnterprise Audio\/Video switch with (24) 10G PoE+++ ports and (4) 100G QSFP28 uplinks. Supports PTP timing, SMPTE ST 2110, SDVoE, and AES67 audio, with a high-precision OCXO clock and optional GPS grandmaster input (SMA) for deterministic media synchronization. Includes Etherlighting™ support.\u003c\/p\u003e\n\u003cp\u003e\u003csub\u003e\u003cstrong\u003eNote.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2,150W total PoE availability requires Shared Mode (coming soon).\u003cbr\u003eRequires a 4-post rack, or a center-mount bracket or cantilever shelf on 2-post racks for optimal support.\u003c\/sub\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"1\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable data-path-to-node=\"2\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,1,0,0\"\u003e\u003cb data-path-to-node=\"2,1,0,0\" data-index-in-node=\"0\"\u003ePhysical\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,1,1,0\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,1,2,0\"\u003e442.4 x 480 x 43.7 mm (17.4 x 18.9 x 1.7\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,2,1,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,2,2,0\"\u003e9.85 kg (21.7 lb) \/ 9.95 kg (21.9 lb) with brackets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,3,1,0\"\u003eEnclosure Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,3,2,0\"\u003eSGCC Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,4,1,0\"\u003eForm Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,4,2,0\"\u003e1U Rack Mount (Full-Depth)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,5,0,0\"\u003e\u003cb data-path-to-node=\"2,5,0,0\" data-index-in-node=\"0\"\u003ePort Layout\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,5,1,0\"\u003e10 GbE RJ45\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,5,2,0\"\u003e24 Ports (All PoE+++)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,6,1,0\"\u003e100G QSFP28\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,6,2,0\"\u003e4 Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,7,1,0\"\u003e1 GbE RJ45\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,7,2,0\"\u003e1 Management Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,8,1,0\"\u003eConsole\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,8,2,0\"\u003e1 Serial \/ 1 SMA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,9,0,0\"\u003e\u003cb data-path-to-node=\"2,9,0,0\" data-index-in-node=\"0\"\u003eDisplay\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,9,1,0\"\u003eLCM\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,9,2,0\"\u003e1.3\" Touchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,10,0,0\"\u003e\u003cb data-path-to-node=\"2,10,0,0\" data-index-in-node=\"0\"\u003eVisuals\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,10,1,0\"\u003eEtherlighting™\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,10,2,0\"\u003eSupported (Ethernet \u0026amp; QSFP28)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"4\"\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"4\"\u003ePoE \u0026amp; Power Delivery\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003e\u003cb data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\"\u003ePoE Standards\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003ePoE (15.4W), PoE+ (30W), PoE++ (60W), PoE+++ (90W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003e\u003cb data-path-to-node=\"5,2,0,0\" data-index-in-node=\"0\"\u003eMax. PoE Availability\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003e\u003cb data-path-to-node=\"5,2,1,0\" data-index-in-node=\"0\"\u003eShared Mode:\u003c\/b\u003e 2,150W (200-240V) \/ 1,850W (100-120V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003e\u003cb data-path-to-node=\"5,3,1,0\" data-index-in-node=\"0\"\u003eRedundant Mode:\u003c\/b\u003e 1,050W (200-240V) \/ 850W (100-120V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003e\u003cb data-path-to-node=\"5,4,0,0\" data-index-in-node=\"0\"\u003ePower Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003e(2) Hot-swappable 1,200W AC\/DC modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003e\u003cb data-path-to-node=\"5,5,0,0\" data-index-in-node=\"0\"\u003ePower Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003e150W (Excluding PoE) \/ 2,400W (Full PoE Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003e\u003cb data-path-to-node=\"5,6,0,0\" data-index-in-node=\"0\"\u003eHeat Dissipation\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,1,0\"\u003e512 BTU\/hr (Excluding PoE Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"7\"\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"7\"\u003ePerformance \u0026amp; Layer 3 Capabilities\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance Metric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003e\u003cb data-path-to-node=\"8,1,0,0\" data-index-in-node=\"0\"\u003eSwitching Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003e1,280 Gbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003e\u003cb data-path-to-node=\"8,2,0,0\" data-index-in-node=\"0\"\u003eNon-Blocking Throughput\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003e640 Gbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003e\u003cb data-path-to-node=\"8,3,0,0\" data-index-in-node=\"0\"\u003eForwarding Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003e810 Mpps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003e\u003cb data-path-to-node=\"8,4,0,0\" data-index-in-node=\"0\"\u003eMAC Address Table\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e32,000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003e\u003cb data-path-to-node=\"8,5,0,0\" data-index-in-node=\"0\"\u003ePacket Buffer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e8 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003e\u003cb data-path-to-node=\"8,6,0,0\" data-index-in-node=\"0\"\u003eIPv4 Routes\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e256,000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003e\u003cb data-path-to-node=\"8,7,0,0\" data-index-in-node=\"0\"\u003eARP Entries\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e128,000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003e\u003cb data-path-to-node=\"8,8,0,0\" data-index-in-node=\"0\"\u003eStatic Routes\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e512\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003e\u003cb data-path-to-node=\"8,9,0,0\" data-index-in-node=\"0\"\u003eL3 Features\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003eDHCP Server\/Relay, Inter-VLAN Routing, Static Routing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"10\"\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eLayer 2 \u0026amp; Pro AV Features\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"11\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,0,0\"\u003e\u003cb data-path-to-node=\"11,1,0,0\" data-index-in-node=\"0\"\u003eStandard L2\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,1,0\"\u003eSTP\/RSTP, LACP, Jumbo Frames, LLDP-MED, IGMP Snooping\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,0,0\"\u003e\u003cb data-path-to-node=\"11,2,0,0\" data-index-in-node=\"0\"\u003ePro AV\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,1,0\"\u003ePTPv2, SyncE, Advanced IGMP (Querier\/Fast Leave)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,0,0\"\u003e\u003cb data-path-to-node=\"11,3,0,0\" data-index-in-node=\"0\"\u003eAV Profiles\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,1,0\"\u003eDante, Q-SYS, NDI, SDVoE, Shure, AES67, Crestron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,0,0\"\u003e\u003cb data-path-to-node=\"11,4,0,0\" data-index-in-node=\"0\"\u003eSecurity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,1,0\"\u003e802.1X, DHCP Snooping, Port Isolation, Storm Control, MAC\/IP ACLs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,0,0\"\u003e\u003cb data-path-to-node=\"11,5,0,0\" data-index-in-node=\"0\"\u003eManagement\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,1,0\"\u003eEthernet, AR (Augmented Reality), Serial Console\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eEnvironmental \u0026amp; Compliance\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"14\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,1,0,0\"\u003e\u003cb data-path-to-node=\"14,1,0,0\" data-index-in-node=\"0\"\u003eCooling\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,1,1,0\"\u003e(4) Hot-swappable fan modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,2,0,0\"\u003e\u003cb data-path-to-node=\"14,2,0,0\" data-index-in-node=\"0\"\u003eOperating Temp\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,2,1,0\"\u003e-5 to 40° C (23 to 104° F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,3,0,0\"\u003e\u003cb data-path-to-node=\"14,3,0,0\" data-index-in-node=\"0\"\u003eOperating Humidity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,3,1,0\"\u003e10 to 90% noncondensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,4,0,0\"\u003e\u003cb data-path-to-node=\"14,4,0,0\" data-index-in-node=\"0\"\u003eESD Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,4,1,0\"\u003eAir: ± 12KV, Contact: ± 8KV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,5,0,0\"\u003e\u003cb data-path-to-node=\"14,5,0,0\" data-index-in-node=\"0\"\u003eCompliance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,5,1,0\"\u003eNDAA Compliant, CE, FCC, IC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csub\u003e\u003cbr\u003e\u003c\/sub\u003e\u003c\/p\u003e","brand":"Ubiquiti","offers":[{"title":"Default Title","offer_id":46151686521028,"sku":"EAV-XG-24-PoE (2150W)","price":3999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/2649\/1076\/files\/Screenshot2026-04-17140136.png?v=1778872240","url":"https:\/\/avdepot.net\/products\/ubiquiti-eav-fiber-enterprise-audio-video-fiber-copy","provider":"AV Depot","version":"1.0","type":"link"}