{"product_id":"altronix-t3lmk77f16n-altx-lm-16dr-12-24v-fused-115v","title":"Altronix T3LMK77F16N ALTX\/LM\/16DR\/12\u002624V\/FUSED\/115V","description":"T3LMK77F16N ALTX\/LM\/16DR\/12\u0026amp;24V\/FUSED\/115V\n\nAltronix T3LMK77F16N kit consists of Trove3 enclosure and TM3 Altronix \u0026amp; LiftMaster backplane with two (2) 24VDC @ 10A power supply\/chargers, two (2) 12VDC voltage regulators, two (2) eight (8) fuse protected output dual voltage power distribution modules, two (2) eight (8) dual voltage fuse protected output access control modules and two (2) 5-Port \nHardened PoE+ Switches. This kit also accommodates up to eight (8) LiftMaster Smart Access 2-Door Controller (CAP2D) for up to sixteen (16) doors in a single enclosure. Four (4) LMBK2 mounting brackets for LiftMaster CAP2D are factory installed. Trove simplifies board layout and wire management, reduces installation time and labor costs.\n\n\nTwo (2) eFlow104NB Power Supply\/Chargers\nInput\nVoltage: 120VAC, 60Hz, 4.5A.\nInput Fuse: 6.3A\/250V\n\nOutputs\nVoltage: 24VDC.\nCurrent: 10A continuous.\nAuxiliary: 1A (unswitched).\nOther: Overvoltage protection. Filtered and regulated.\n\n\nBattery Charging\nCapacity: 12VDC\/12AH (4 within enclosure); 40AH\/65AH (requires separate enclosure).\nType: Sealed lead acid or gel type.\nFailover: Upon AC loss, instantaneous.\n\u003ci\u003e(Batteries are sold separately).\u003c\/i\u003e\n\nSupervision\nAC Failure: Form “C” contacts.\nBattery: Form “C” contacts.\nLow DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.\n\nIndicators LED\nInput: 120VAC is present.\nDC Output: Powered.\nBattery: Discharged or not connected.\n\nTwo (2) ACMS8 Dual Input Access Power Controllers\nInput\nVoltage: 24VDC from eFlow104NTB and 12VDC from VR6.\nInput Fuse: 15A \/ 32V.\n\nOutputs\nVoltage: 12 or 24VDC individually selectable.\nEight (8) selectable 12VDC - 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs:\n b) Form “C” Relays rated 28VAC or VDC @ 2.5A Rated.\n c) Auxiliary power outputs (unswitched).\n d) Any combination of the above.\n Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.\n Individual outputs may be set to OFF position for servicing.\n\nOutputs Ratings\nFuses: 3A\/32V.\n\nIndicators (LED's)\nRed LEDs: Outputs are triggered (relays energized).\nBlue LED: FACP disconnect is triggered.\nIndividual voltage LEDs:\nGreen: 12VDC.\nRed: 24VDC.\n\n\nTwo (2) VR6 Voltage Regulators\nInput\nVoltage: 24VDC from eFlow104NTB\n\nOutput\nVoltage: 12VDC.\nCurrent: 6A continuous.\nOther: Surge suppression.\n\nIndicators LED\nInput: 24VDC is present.\nOutput: Powered.\n\n\nTwo (2) PDS8 Dual Input Power Distribution Modules\nInput\nVoltage: 24VDC from eFlow104NTB and 12VDC from VR6\nInput Fuse: 10A \/ 32V\n\nOutputs\nVoltage: 12VDC and\/or 24VDC\nAny of the eight (8) power outputs are selectable to follow power Input 1 or Input 2\nIndividual outputs may be set to OFF position for servicing\n\nOutputs Ratings\nFuses: 3A\/32V\n\nIndicators (LED)\nDC Output: Eight (8) individual output LEDs\nGreen: 12VDC\nRed: 24VDC.\n\n\nTwo (2) NetWay5P 5-Port PoE+ Hardened Switches\nInput Power\n24VDC from eFlow104NTB\n\nPower Output\nMaximum Power: Four (4) 10\/100\/1000 Mbps, PoE\/PoE+ (rated up to 30W) ports, 60W (at 12VDC) or 120W (at 24VDC) total power, Integral surge protection\nUplink Port: Single data port\n\nEthernet Ports:\nFive (5) 10\/100\/1000 Mbps ports.\nConnectivity: RJ45, auto-crossover.\nWire type: 4-pair CAT5 or better structured cable.\nDistance: up to 100m.\nSpeed: 10\/100\/1000 Mbps, half\/full duplex, auto negotiation.\n\nIndicators (LED)\nIndividual \u003cstrong\u003ePoE On\u003c\/strong\u003e LEDs for each port.\nIndividual \u003cstrong\u003eIP Link status, 10\/100Base-T\/active\u003c\/strong\u003e LEDs for each port.\n\n\nEnvironmental\nTemperature\nOperating: 0° C to 49° C (32° F to 120° F).\nStorage: - 20° C to 70° C ( - 4° F to 158° F).\n\nRelative Humidity\nRelative Humidity: 85%  +\/- 5%.\n\nBTU\/Hr. (approx.):\n145 BTU\/Hr.","brand":"Altronix","offers":[{"title":"Default Title","offer_id":46151447150788,"sku":"T3LMK77F16N","price":2391.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/2649\/1076\/files\/main_3299de2b-42c4-4b9b-b467-80e2f57834a2.jpg?v=1778870983","url":"https:\/\/avdepot.net\/products\/altronix-t3lmk77f16n-altx-lm-16dr-12-24v-fused-115v","provider":"AV Depot","version":"1.0","type":"link"}