{"product_id":"altronix-t2mk3f8q2-t2m2-8dr-6a-fuse-lq2","title":"Altronix T2MK3F8Q2 T2M2, 8DR, 6A, FUSE, LQ2","description":"T2MK3F8Q2 T2M2, 8DR, 6A, FUSE, LQ2\n\nAltronix T2MK3F8Q2 kit consists of Trove2 enclosure and TM2 Mercury\/Altronix backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply\/charger, Network communication module, and eight (8) fuse protected output access control module. This kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.\n\u003cbr\u003e\n*Compatible with these authentic Mercury partners:\u003cbr\u003e\nAccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel\/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt\n\n\neFlow6NB Power Supply\/Charger\nInput\nVoltage: 120VAC, 60Hz.\nInput Fuse: 5A \/ 250V.\n\nOutputs\nVoltage: 24VDC.\nCurrent: 6A continuous.\nOther: Overvoltage protection. Filtered and regulated.\n\n\nBattery Charging\nCapacity 7AH\/12VDC (Up to 2 within enclosure); 40 AH\/65 AH (requires separate enclosure)\nType: Sealed lead acid or gel type\nFailover: Upon AC loss, instantaneous\n\u003ci\u003e(Batteries are sold separately).\u003c\/i\u003e\n\nSupervision\nAC Failure: Form “C” contacts.\nBattery: Form “C” contacts.\nLow DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.\n\nIndicators LED\nInput: 120VAC is present.\nDC Output: Powered.\nBattery: Discharged or not connected.\n\nLINQ2 Network Communication Module\nStatus Monitoring\nAC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery\/Battery presence detection.\nInput trigger state change; Output (relay and power supply) state change.\n\nProgramming\nBattery service date indication.\nProgrammable via USB or web browser.\nAutomated timed events: Control output relays and power supply via flexible timing parameter.\n\nReporting\nProgrammable dashboard notifications.\nE-mail notification selectable by event.\nEvent log tracks history (100+ events).\n\nIndicators (LED)\nBlue LED: Power ON.\n\n\nACM8 Access Power Controller\nInput\nVoltage: 24VDC from eFlow6NB.\nInput Fuse: 10A \/ 250V.\n\nOutputs\nVoltage: 24VDC.\nEight (8) 24VDC independently controlled fused outputs:\na) Fail-Safe and\/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.\nb) Auxiliary power outputs (unswitched).\nc) Any combination of the above.\n\nOutput Fuses\n3.5A\/250V.\n\nIndicators (LED)\nRed LEDs: Outputs are triggered (relays energized).\nGreen LED: FACP disconnect is triggered.\n\n\nEnvironmental\nTemperature\nOperating: 0° C to 49° C (32° F to 120° F).\nStorage: - 20° C to 70° C ( - 4° F to 158° F).\n\nRelative Humidity\n85%  +\/- 5%.\n\nBTU\/Hr. (approx.):\n87 BTU\/Hr.","brand":"Altronix","offers":[{"title":"Default Title","offer_id":46151437680836,"sku":"T2MK3F8Q2","price":953.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/2649\/1076\/files\/main_1a374f05-0ced-4026-803a-10c644a8269e.jpg?v=1778870950","url":"https:\/\/avdepot.net\/products\/altronix-t2mk3f8q2-t2m2-8dr-6a-fuse-lq2","provider":"AV Depot","version":"1.0","type":"link"}