{"product_id":"altronix-maximal1r-12vdc-4a-24vdc-3a-16-fused-ou","title":"Altronix MAXIMAL1R 12VDC@4A\/24VDC@3A, 16 FUSED OU","description":"Altronix MAXIMAL1R 12VDC@4A\/24VDC@3A, 16 FUSED OU\n\nMaximal1R rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 115VAC 50\/60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and\/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.\n\n\nInput\n115VAC 60Hz., 1.9A.\nNormally closed [NC] or normally open [NO] dry contact inputs (switch selectable).\n\nOutputs\n12VDC @ 4A or 24VDC @ 3A total output current.\nSixteen (16) fuse protected outputs.\nMaximum current per ACM8R-M output is 2.5A.\nIndividually selectable Mag Lock\/Strike (Fail-Safe, Fail-Secure) solid state fuse protected outputs.\nThermal and short circuit protection with auto reset.\n\nFire Alarm Interface\nLatching or Non-Latching fire alarm reset switch individually selectable for each output.\nRemote reset capability for latching Fire Alarm Interface mode.\nFire Alarm disconnect input options:\na) Normally open [NO] or normally closed [NC] dry contact input.\nb) Polarity reversal input from FACP signaling circuit.\n\n\nVisual Indicators\nIndividual Output Status LEDs located on the front panel.\n\nBattery Charging\nType: Sealed lead acid or gel type.\nFailover: Upon AC loss, instantaneous.\n\u003ci\u003e(Batteries are sold separately).\u003c\/i\u003e\n\nSupervision\nAC fail supervision (form \"C\" contacts).\nNotification trigger is selectable for 30 seconds (factory set) or 6 hours.\nLow battery and battery presence supervision (form \"C\" contact).\n\nAdditional Features\nRemovable terminal blocks with locking screw flange.\n3-wire line cord.\nIlluminated master power disconnect circuit breaker with manual reset.\n\nElectrical\nTemperature:\nOperating: 0° C to 49° C (32° F to 120° F).\nStorage: - 20° C to 70° C ( - 4° F to 158° F).\n\nRelative Humidity: 85%  +\/- 5%.\nBTU\/Hr. (approx.):\n12VDC: 25 BTU\/Hr.\n24VDC: 37 BTU\/Hr.\n\nSystem AC input VA requirement: 218.5VA.","brand":"Altronix","offers":[{"title":"Default Title","offer_id":46151404716228,"sku":"MAXIMAL1R","price":591.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/2649\/1076\/files\/main_3a068c56-9245-41c2-a564-c6d6da9603a4.jpg?v=1778870786","url":"https:\/\/avdepot.net\/products\/altronix-maximal1r-12vdc-4a-24vdc-3a-16-fused-ou","provider":"AV Depot","version":"1.0","type":"link"}