{"product_id":"altronix-maximal11d-12vdc-8a-24vdc-6a-16-ptc-out","title":"Altronix MAXIMAL11D 12VDC@8A\/24VDC@6A, 16 PTC OUT","description":"Altronix MAXIMAL11D 12VDC@8A\/24VDC@6A, 16 PTC OUT\n\nMaximal11D distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC and\/or 24VDC PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and\/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.\n\n\nInput\n115VAC 60Hz, 7.0A  input.\nPower supply input options: \na) Two (2) common power input for either ACM8CB and lock power (factory installed).\nb) Two (2) isolated power inputs (external power supply is required), (current is determined by the power supply connected, not to exceed a maximum of 10A total).\n\nSixteen (16) Access Control System trigger inputs.\nInput options:\na) Sixteen (16) normally open (NO) inputs.\nb) Sixteen (16) open collector inputs.\nc) Any combination of the above.\n\n\nOutput\n12VDC and\/or 24VDC outputs.\nMaximum output current Options:\nA) 12VDC @ 3.5A plus 12VDC @ 3.5A.\nB) 24VDC @ 2.7A plus 24VDC @ 2.7A.\nC) 12VDC @ 3.5A plus 24VDC @ 2.7A.\n\nClass 2 Rated power limited outputs (auto-resettable).\nSixteen (16) independently controlled outputs can be Fail-Safe and\/or Fail-Secure power outputs.\nSixteen (16) auxiliary power outputs (unswitched), (outputs are rated 2A).\nFiltered and electronically regulated outputs (built-in power supply).\nThermal and short circuit protection with auto reset.\n\nFuse Ratings\nPower Supply input fuse rated @ 3.5A\/250V.\nACM8CB boards main fuse is rated at 10A Output fuses are rated @ 2.5A.\n\nFeatures\nFire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.\nFire Alarm disconnect input options:\na) Normally open (NO) or normally closed (NC) dry contact input.\nb) Polarity reversal input from FACP signaling circuit.\n\nAlarm output relay indicates that FACP input is triggered (form \"C\" contact rated @ 1A 28VDC).\n\nSupervision\nAC fail supervision (form \"C\" contacts).\nNotification trigger is selectable for 30 seconds (factory set) or 6 hours.\nLow battery and battery presence supervision (form \"C\" contact).\n\nBattery Charging\nCapacity: 12AH\/12VDC (4 within enclosure); 40AH\/65AH (requires separate enclosure).\nType: Sealed lead acid or gel type.\nFailover: Upon AC loss, instantaneous.\n\u003ci\u003e(Batteries are sold separately).\u003c\/i\u003e\n\nVisual Indicators\nRed LEDs indicate outputs are triggered (relays energized).\nGreen LED indicates FACP disconnect is triggered.\nAC input and DC output LED indicators.\n\nElectrical\nTemperature:\nOperating: 0° C to 49° C (32° F to 120° F).\nStorage: - 20° C to 70° C ( - 4° F to 158° F).\n\nRelative Humidity: 85%  +\/- 5%.\nBTU\/Hr. (approx.):\n12VDC: 43 BTU\/Hr.\n24VDC: 66 BTU\/Hr.\n12VDC \u0026amp; 24VDC: 55 BTU\/Hr.\n\nSystem AC input VA requirement: 805VA.","brand":"Altronix","offers":[{"title":"Default Title","offer_id":46151403143364,"sku":"MAXIMAL11D","price":854.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/2649\/1076\/files\/main_41d5ba8f-901d-478f-ab6e-975ed4daf5e0.jpg?v=1778870781","url":"https:\/\/avdepot.net\/products\/altronix-maximal11d-12vdc-8a-24vdc-6a-16-ptc-out","provider":"AV Depot","version":"1.0","type":"link"}