{"product_id":"altronix-acms8k1-vr6-acms8-kit","title":"Altronix ACMS8K1 VR6\/ACMS8 KIT","description":"\u003cp\u003e\u003cstrong\u003eAltronix ACMS8K1 VR6\/ACMS8 KIT\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003cp\u003eAltronix VR6 Voltage Regulator converts a 24VDC input into a regulated 5VDC or 12VDC selectable output at up to 6A supply current. It reduces the cost of adding an additional power supply to achieve 24VDC and 12VDC or 5VDC simultaneously, saving valuable \u003cbr\u003eenclosure space. Altronix ACMS8 dual input design allows power to be steered from two (2) independent low voltage 12 or 24 VDC power sources into eight (8) independently controlled fuse protected outputs. In ACMS8, these power outputs can also be converted to dry form “C” contacts. Outputs are activated by an open collector sink, normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACMS8 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and\/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to daisy chain power to multiple ACMS8 modules. This feature allows you to distribute the power over more outputs for larger systems.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003eVR6 \u003cbr\u003e\u003cstrong\u003ePower Input \/ Output: \u003c\/strong\u003e\u003cbr\u003eInput: 24VDC @ 1.75A – Output: 5VDC @ 6A. \u003cbr\u003eInput: 24VDC @ 3.5A – Output: 12VDC @ 6A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: \u003c\/strong\u003e\u003cbr\u003e5VDC or 12VDC regulated output. \u003cbr\u003eOutput rating 6A max. non power-limited. \u003cbr\u003eSurge suppression.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators: \u003c\/strong\u003e\u003cbr\u003eInput and output LEDs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBTU\/Hr (approx.): \u003c\/strong\u003e\u003cbr\u003e5VDC: 15 BTU\/Hr. \u003cbr\u003e12VDC: 37 BTU\/Hr.\u003c\/p\u003e\n\u003cp\u003eACMS8 \u003cbr\u003e\u003cstrong\u003ePower Input \/ Voltage Range: \u003c\/strong\u003e\u003cbr\u003e5VDC to 24VDC, up to 10A each or 20A total input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEight (8) Individually Controlled trigger inputs: \u003c\/strong\u003e\u003cbr\u003ea) Normally open (NO) inputs. \u003cbr\u003eb) Normally closed (NC) inputs. \u003cbr\u003ec) Open collector sink inputs. \u003cbr\u003ed) Wet Input (5VDC - 24VDC) with 10K resistor. \u003cbr\u003ee) Any combination of the above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs: \u003c\/strong\u003e\u003cbr\u003eFuse protected outputs rated @ 2.5A per output, non power-limited. Total output 20A max. \u003cbr\u003eDo not exceed the individual power supply ratings. \u003cbr\u003ea) Fail-Safe and\/or Fail-Secure power outputs. \u003cbr\u003eb) Form “C” Relays. Contacts rated @ 2.5A. \u003cbr\u003ec) Auxiliary power outputs (unswitched). \u003cbr\u003ed) Any combination of the above. \u003cbr\u003eIndividual outputs may be set to OFF position for servicing (output jumper set to middle position). \u003cbr\u003eDoes not apply to Dry Contact applications. \u003cbr\u003eAny of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2. \u003cbr\u003eOutput voltage of each output is the same as the input voltage of the input selected. \u003cbr\u003eSurge suppression.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFire Alarm Disconnect \u003c\/strong\u003e\u003cbr\u003eFire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFire Alarm disconnect input options: \u003c\/strong\u003e\u003cbr\u003ea) Normally open [NO] or normally closed [NC] dry contact input. Polarity reversal input from FACP signaling circuit. \u003cbr\u003eFACP output relay [NC] contact or provides 10k resistance with [EOL JMP] intact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Ratings \u003c\/strong\u003e\u003cbr\u003eFuses are rated 2.5A each. \u003cbr\u003eMain input fuses rated @ 15A\/32V each.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators \u003c\/strong\u003e\u003cbr\u003eRed LEDs indicate outputs are triggered. \u003cbr\u003eBlue LED indicates FACP disconnect is triggered.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndividual voltage LEDs \u003c\/strong\u003e\u003cbr\u003eGreen: 12VDC \u003cbr\u003eRed\/Green: 24VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBTU\/Hr (approx.): \u003c\/strong\u003e\u003cbr\u003e4 BTU\/Hr.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature for (ACMS8, VR6): \u003c\/strong\u003e\u003cbr\u003eOperating Temperature 0ºC to 49ºC (32ºF to 120ºF). \u003cbr\u003eStorage Temperature - 20ºC to 70ºC ( - 4ºF to 158ºF). \u003cbr\u003eRelative Humidity 85% +\/- 5%.\u003c\/p\u003e","brand":"Altronix","offers":[{"title":"Default Title","offer_id":46151384432836,"sku":"ACMS8K1","price":183.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/2649\/1076\/files\/main_3a571e32-579f-4427-ae2e-f063732a9df8.jpg?v=1778870691","url":"https:\/\/avdepot.net\/products\/altronix-acms8k1-vr6-acms8-kit","provider":"AV Depot","version":"1.0","type":"link"}