{"product_id":"altronix-acms8-2-input-8-ch-acces-power-cont","title":"Altronix ACMS8 2 INPUT, 8 CH ACCES POWER CONT","description":"\u003cp\u003e\u003cstrong\u003eAltronix ACMS8 2 INPUT, 8 CH ACCES POWER CONT\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003cp\u003eAltronix ACMS8 is UL listed sub-assemblies designed to be used in Altronix wall and rack mount enclosures. Input power to ACMS8 is to be derived from eFlow series power supplies. Dual input design allows power to be steered from two (2) independent low voltage 5 to 24 VDC power sources into eight (8) independently controlled fuse protected outputs. In ACMS8, these power outputs can also be converted to dry form “C” contacts. Outputs are activated by an open collector sink, normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACMS8 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and\/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to daisy chain power to multiple ACMS8 module. This feature allows you to distribute the power over more outputs for larger systems.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eInput\u003c\/strong\u003e \u003cbr\u003eTwo (2) independent low voltage inputs. \u003cbr\u003e1) Input: 12 or 24VDC from eFlow series Altronix Power supply. \u003cbr\u003e2) Input: 12 or 24 VDC from eFlow series Altronix power supply or either 5 or 12 VDC from VR6 Regulator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range \u003c\/strong\u003e\u003cbr\u003e20A total input. \u003cbr\u003eMain Fuse Rating 15\/32A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption: \u003c\/strong\u003e\u003cbr\u003e0.6A @ 12V, 0.3A @ 24V with all relays energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger Inputs \u003c\/strong\u003e\u003cbr\u003eEight (8) individually controlled trigger inputs: \u003cbr\u003ea) Normally open (NO) inputs. \u003cbr\u003eb) Normally closed (NC) inputs. \u003cbr\u003ec) Open collector sink inputs. \u003cbr\u003ed) Wet Input (5VDC - 24VDC) with 10K resistor. \u003cbr\u003ee) Any combination of the above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e \u003cbr\u003eFuse protected outputs rated @ 2.5A per output, non power-limited. Total output 20A max. \u003cbr\u003eDo not exceed the individual power supply ratings. \u003cbr\u003eEight (8) selectable 5VDC - 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs: \u003cbr\u003ea) Fail-Safe and\/or Fail-Secure power outputs. \u003cbr\u003eb) Form “C” Relays. 28VAC or VDC @ 2.5A Rated. \u003cbr\u003ec) Auxiliary power outputs (unswitched). \u003cbr\u003ed) Any combination of the above. \u003cbr\u003eAny of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2. \u003cbr\u003eIndividual outputs may be set to OFF position for servicing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Ratings \u003c\/strong\u003e\u003cbr\u003eFuses are rated 3A\/32V each. \u003cbr\u003eTotal output current is determined by the power supply(ies), not to exceed a maximum of 10A for each input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFire Alarm Disconnect \u003c\/strong\u003e\u003cbr\u003eFire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs. \u003cbr\u003eFire Alarm disconnect input options: \u003cbr\u003ea) Normally open [NO] or normally closed [NC] dry contact input. Polarity reversal input from FACP signaling circuit.\u003c\/p\u003e\n\u003cp\u003eFACP output relay [NC] contact or provides 10k resistance with [EOL JMP] intact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators \u003c\/strong\u003e\u003cbr\u003eRed LEDs indicate outputs are triggered. \u003cbr\u003eBlue LED indicates FACP disconnect is triggered. \u003cbr\u003eIndividual voltage LEDs \u003cbr\u003eGreen: 12VDC \u003cbr\u003eRed: 24VDC.\u003c\/p\u003e\n\u003cp\u003eTemperature \u003cbr\u003eOperating: 0ºC to 49ºC (32ºF to 120ºF). \u003cbr\u003eStorage: -20ºC to 70ºC (-4ºF to 158ºF). \u003cbr\u003eRelative Humidity: 93% +\/-5%. \u003cbr\u003eBTU\/Hr. (approx.): 4 BTU\/Hr.\u003c\/p\u003e","brand":"Altronix","offers":[{"title":"Default Title","offer_id":46151385678020,"sku":"ACMS8","price":132.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/2649\/1076\/files\/main_1f9471df-749f-42da-81fd-5a468d3038de.jpg?v=1778870692","url":"https:\/\/avdepot.net\/products\/altronix-acms8-2-input-8-ch-acces-power-cont","provider":"AV Depot","version":"1.0","type":"link"}